6.0 Installation – [cont’d]
Fig. 6-7 Location of Port ‘G’ On Valve Housing Identified.
Fig. 6-8 Three Pump Elements Bridged Into Single Line To Breaker
6.3.4 (H) Three Elements Into Single Lube Line
1. If not already installed, refer to the pump element
instructions in Section 6.6. Refer to above figure
for assembly of 3-element adapter kit.
2. Route lube lines along the existing hydraulic
hoses. Allow for proper slack at pivot joints.
IMPORTANT
Route hoses avoiding sharp bends. Wrap any hose
susceptible to damage from rubbing. Before cutting
hose, check for proper length to both termination
points, knowing where each component mounts.
3. Measure, cut and assemble connectors to lube
lines according to figure 6-3. Quick disconnect
couplers are provided for easy connection and
removal of the breaker.
-MIN-
-MAX-
BreakerLube
E
-MIN-
-MAX-
H