Camera interfaces
58
Bonito PRO Technical Manual V1.0.0
The General Purpose I/O port uses a Hirose HR10A-10R-12PB connector on the
camera side. The mating cable connector is Hirose HR10A-10P-12S.
I/O definition
Camera Power
The Bonito PRO camera can be powered through the Hirose I/O port, via
Pin 1
Camera GND and
Pin 2
Camera Power, or through the CoaXPress interface if using
a Power over CoaXPress (PoCXP) supported frame grabber.
Cameras powered by both the Hirose I/O port and the CoaXPress interface uses
the power provided by Hirose I/O port only.
Pin 2
, Camera Power, supports an input voltage of 24 VDC ± 2.4 VDC. The camera
does not power in reverse polarity. Exceeding the 24 VDC ± 2.4 VDC could damage
the camera.
Input triggers
Input triggers allow the camera to be synchronized to an external event. The
camera can be programmed to trigger on the rising edge, falling edge, both edges,
or level of the signal. The camera can also be programmed to capture an image at
some programmable delay time after the trigger event.
In 1 (Non-isolated)
In 1
is not electrically isolated and can be used when environmental noise is
insignificant and faster trigger response is required. The required trigger signal is
low voltage TTL 3.3 VDC. Tie trigger ground to Camera GND to complete the trigger
circuit.
Hirose connector
The cable side Hirose 12-pin female connector is available for purchase from Allied
Vision. Order code: K7600040.
NOTICE
Power caution
Exceeding 5.1 VDC on
In 1
can permanently damage the camera.