User profiles
Definition
Within the IIDC specification user profiles are called memory channels. Often
they are called user sets. In fact these are different expressions for the fol-
lowing: storing camera settings into a non-volatile memory inside the cam-
era.
User profiles can be programmed with the following advanced feature regis-
ter:
In general this advanced register is a wrapper around the standard memory
channel registers with some extensions. So to query the number of available
user profiles you have to check the
Memory_Channel
field of the
BASIC_FUNC_INQ
register at offset
0x400
(see IIDC V1.31 for details).
The
ProfileID
is equivalent to the memory channel number and specifies the
profile number to store settings to or to restore settings from. In any case
profile #0 is the hard-coded factory profile and cannot be overwritten.
After an initialization command, startup or reset of the camera, the
ProfileID
also indicates which profile was loaded on startup, reset or initialization.
Offset
Name
Field
Bit
Description
0xF1000550
USER_PROFILE
Presence_Inq
[0]
Indicates presence of this feature
(read only)
Error
[1]
An error occurred
---
[2..6]
Reserved
Busy
[7]
Save/Load in progress
Save
[8]
Save settings to profile
Load
[9]
Load settings from profile
SetDefaultID
[10]
Set Profile ID as default
---
[11..19]
Reserved
ErrorCode
[20..23]
Error code
See
Table 184: User profiles: Error
---
[24..27]
Reserved
ProfileID
[28..31]
ProfileID (memory channel)
Table 183: Advanced register:
User profiles