Description of the data path
PIKE Technical Manual
V5.0.0
150
Note
•
The input value is the
14-bit
value from the digitizer.
•
The two gamma LUTs use LUT 14 and 15.
•
Gamma 1 (gamma=0.7) switches on LUT 14, gamma 2
(gamma=0.45) switches on LUT 15. After overriding
LUT 14 and 15 with a user defined content, gamma
functionality is no longer available until the next full
initialization of the camera.
•
LUT content is volatile if you do not use the user pro-
files to save the LUT.