Controlling image capture
PIKE Technical Manual
V5.0.0
211
Which new sequence mode features are
available?
New features:
•
Repeat one step of a sequence n times where n can be set by the vari-
able
ImageRepeat
in SEQUENCE_PARAM.
•
Define one or two hardware inputs in Input mode field of IO_INP_CTRL
as:
– Sequence step input (if two are set as input, they are AND gated) or
– Sequence reset input
Setup mode
The
SetupMode
flag allows you to set up a sequence while capturing images.
Using this flag you get a visual feedback of the settings. Set this flag when
setting up the sequence and reset the flag before using the sequence.
I/O controlled sequence stepping mode
The
I/O controlled sequence stepping mode
can be done level controlled
or edge controlled:
The
I/O controlled sequence stepping mode
can be set for every single
sequence entry. Thus a sequence can be controlled in a very flexible manner.
Note
From now on:
sequence step is
I/O controlled sequence stepping mode
sequence reset is
I/O controlled sequence pointer reset
Level controlled
Edge controlled
•
As long as the input is in high
state the sequence pointer will
be incremented from image to
image.
•
Can be combined with
Quick
Format Change Modes
. See
167.
•
Level change is asynchronous to
image change.
•
A rising edge on the input will
cause one pointer increment
immediately.
•
Can be combined with
Quick
Format Change Modes
. See
on page 167 and
Table 74: Description of sequence stepping control