Controlling image capture
PIKE Technical Manual
V5.0.0
214
Changing the parameters within a sequence
To change the parameter set for one image, it is not necessary to modify the
settings for the entire sequence. The image can simply be selected via the
ImageNo
field and it is then possible to change the corresponding IIDC
V1.31 registers.
Points to pay attention to when changing the
parameters
Note
•
If the
ApplyParameters
flag is used when setting the
parameters, all not-configured values are set to default
values. As changing a sequence normally affects only
the value of a specific register, and all other registers
should not be changed, the
ApplyParameters
flag may
not be used here.
•
The values stored for individual images can no longer
be read.
•
If the camera is switched into
sequence mode
, the
changes to the IIDC V1.31 registers for the image spec-
ified in
ImageNo
take immediate effect.
•
Sequence mode requires firmware 3.x and special care if
changing image size and frame rate related parameters.
This is because these changes not only affect settings
in the camera but also require corresponding settings in
the receiving software in the PC (e.g. FirePackage).
Caution
Incorrect handling may lead to
image corruption
or
loss of
subsequent images
.
Please ask for detailed support when you want to use this
feature.