520
Command Reference for IE200 Series Industrial Managed PoE+ Switches
C613-50066-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5I-0.x
P
OWER
OVER
E
THERNET
C
OMMANDS
SHOW
POWER
-
INLINE
COUNTERS
Output
Figure 14-2:
Example output from the
show power-inline counters
command
Related
Commands
clear power-inline counters interface
show power-inline
show power-inline interface
awplus#show power-inline counters interface port1.0.1-port1.0.3
PoE Counters:
Interface MPSAbsent Overload Short Invalid Denied
port1.0.1 0 0 0 0 0
port1.0.2 0 0 0 0 0
port1.0.3 0 0 0 0 0
Table 14-2: Parameters in the
show power-inline counters
command output
Parameter
Description
Interface
The PoE port(s) in the format
portx.y.z
, where
x
is the device
number,
y
is the module number within the device, and
z
is the
PoE port number within the module.
MPSAbsent
The number of instances when the PoE MPS (Maintain Power
Signature) signal has been lost. The PoE MPS signal is lost when a
PD is disconnected from the PSE. Also increments
pethPsePortMPSAbsentCounter
in the PoE MIB.
Overload
The number of instances when a PD exceeds its configured power
limit (as configured by the
power-inline max
command). Also
increments
pethPsePortOverLoadCounter
in the PoE MIB.
Short
The number of short circuits that have happened with a PD. Also
increments
pethPsePortShortCounter
in the PoE MIB.
Invalid
The number of times a PD with an Invalid Signature (where the PD
has an open or short circuit, or is a legacy PD) is detected. Also
increments
pethPseInvalidSignatureCounter
in the PoE
MIB.
Denied
The number of times a PD has been refused power due to power
budget limitations for the PSE. Also increments
pethPsePortPowerDeniedCounter
in the PoE MIB.