1316
Command Reference for IE200 Series Industrial Managed PoE+ Switches
C613-50066-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5I-0.x
SNMP C
OMMANDS
SNMP
-
SERVER
ENABLE
TRAP
Usage
This command cannot be used to enable link status notifications globally. To
enable link status notifications for particular interfaces, use the
snmp trap
link-status
command.
To specify where notifications are sent, use the
snmp-server host
command.
Note that more than one trap can be configured with one command entry, and
also note this command applied to notifications send by SNMP version 3.
Examples
To enable the device to send PoE related traps, use the following commands:
awplus#
configure terminal
awplus(config)#
snmp-server enable trap power-inline
To disable PoE traps being sent out by the device, use the following commands:
awplus#
configure terminal
awplus(config)#
no snmp-server enable power-inline
To enable the device to send MAC address Thrash Limiting traps, use the following
commands:
awplus#
configure terminal
awplus(config)#
snmp-server enable trap thrash-limit
To disable the device from sending MAC address Thrash Limiting traps, use the
following commands:
awplus#
configure terminal
awplus(config)#
no snmp-server enable trap thrash-limit
Related
Commands
show snmp-server
show ip dhcp snooping
snmp trap link-status
snmp-server host