power-inline usage-threshold
Overview
This command sets the level at which the Power Sourcing Equipment (PSE) will
issue a message that the power supplied to all Powered Devices (PDs) has reached
a critical level of the nominal power rating for the PSE. The level is set as a
percentage of total available power.
The
no
variant of this command resets the notification usage-threshold to the
default (80% of the nominal power rating of the PSE).
Syntax
power-inline usage-threshold <
1-99
>
no power-inline usage-threshold
Default
The default power usage threshold is 80% of the nominal power rating of the PSE.
Mode
Global Configuration
Usage
Use the
snmp-server enable trap
command to configure SNMP notification. An
SNMP notification is sent when the usage-threshold, as configured in the example,
is exceeded.
Examples
To generate SNMP notifications when power supplied exceeds 70% of the nominal
PSE power, use the following commands:
awplus#
configure terminal
awplus(config)#
snmp-server enable trap power-inline
awplus(config)#
power-inline usage-threshold 70
To reset the notification threshold to the default (80% of the nominal PSE power
rating), use the following commands:
awplus#
configure terminal
awplus(config)#
no power-inline usage-threshold
Validation
Commands
show power-inline interface
show running-config power-inline
Related
Commands
snmp-server enable trap
Parameter
Description
<
1-99
>
The usage-threshold percentage configured with this
command.