C613-50066-01 REV A
Command Reference for IE200 Series Industrial Managed PoE+ Switches
1421
AlliedWare Plus™ Operating System - Version 5.4.5I-0.x
T
RIGGER
C
OMMANDS
REPEAT
repeat
Overview
This command specifies the number of times that a trigger is permitted to activate.
This allows you to specify whether you want the trigger to activate:
•
only the first time that the trigger conditions are met
•
a limited number of times that the trigger conditions are met
•
an unlimited number of times
Once the trigger has reached the limit set with this command, the trigger remains
in your configuration but cannot be activated. Use the
repeat
command again to
reset the trigger so that it is activated when its trigger conditions are met.
By default, triggers can activate an unlimited number of times. To reset a trigger to
this default, specify either
yes
or
forever
.
Syntax
repeat {forever|no|once|yes|<
1-4294967294
>}
Mode
Trigger Configuration
Examples
To allow trigger
21
to activate only once, use the commands:
awplus#
configure terminal
awplus(config)#
trigger 21
awplus(config-trigger)#
repeat no
To allow trigger
22
to activate an unlimited number of times whenever its trigger
conditions are met, use the commands:
awplus#
configure terminal
awplus(config)#
trigger 22
awplus(config-trigger)#
repeat forever
To allow trigger
23
to activate only the first
10
times the conditions are met, use
the commands:
awplus#
configure terminal
awplus(config)#
trigger 23
awplus(config-trigger)#
repeat 10
Related
Commands
show trigger
trigger
Parameter
Description
yes|forever
The trigger repeats indefinitely, or until disabled.
no|once
The trigger activates only once.
<1-4292967294>
The trigger repeats the specified number of times.