Allied Data Technologies
25
3 -
Start local digital loopback V54, L2
4 -
Confirmation of digital loopback for remote request on (default)
5 -
Confirmation of digital loopback for remote request off
6 -
Request for a remote digital loopback (RDL) V54, L2
7 -
Request for a RDL V54, L2 with self-test
ATV
Terse/verbose response
This command sets the response to the terminal to verbose or terse.
0 -
Terse (numerical) response
1 -
Long (verbose) response (default)
AT&V
Show configuration
This command provides an overview of the present configuration. The
stored settings 0 and 1, the first four stored telephone numbers and the
value of the softkey appear on the screen.
AT&V1
Display data from last connection
This command is used to display the data from the last connection
established by the modem.
AT\V
Number of signal lines for connection
After establishing a connection, the modem can show that the connection
has been established on one or more lines.
0 -
Message on several lines (default)
1 -
Message on one line
ATW
Extended response
This command is used to select the information sent after the CONNECT
message (see also S95).
0 -
The CONNECT message is followed by the terminal speed.
1 -
The CONNECT message is followed by the line speed, the error
correction protocol and the terminal speed.
2 -
The CONNECT message is followed by the line speed (default).