22
Allied Data Technologies
<max_speed> Specifies the highest speed at which the modem may establish a
connection. The default value is 56000 (bps)
AT)M
Adjust send level (MNP10)
This command allows the modem to adjust the send level automatically
during an MNP10 connection.
0 -
Standard send level during MNP10 connections (default)
1 -
Automatic adjustment of send level during MNP10 connections
ATN
Automatic line speed detection
0 -
Automatic line speed detection disabled. The connection is
established according to the contents of register S37
1 -
Automatic line speed detection enabled. This setting is the same
as ATF0 (default).
AT\N
Error correction on/off
This command determines whether or not error correction is performed
during a connection. There are two protocols for a connection with error
correction, namely MNP4 and V42 LAPM.
0 -
Only connections without error correction. Interspeeder on.
Forces AT&Q6.
1 -
This parameter puts the external model into direct mode (AT&Q0).
The internal model works with this parameter as with 0.
2 -
Only connections with error correction. Forces AT&Q5, S36=4,
S48=7.
3 -
Automatic selection between error correction yes/no. Connections
with error correction are preferred, but switching to normal
connections is possible. Forces AT&Q5, S36=7, S48=7 (default).
4 -
V42 LAPM connections only. Forces AT&Q5, S48=0.
5 -
MNP4 connections only. Forces AT&Q5, S36=4, S48=128. Use
this setting with Remote Configuration (see AT*R).
ATO
On line data mode (Originate)