16
Allied Data Technologies
This command is used to determine the line speed during negotiations
between two MNP Class 10 modems. Communication then takes place at
a higher speed.
0 -
Negotiation at the highest supported speed (default)
1 -
Negotiation at 1200 bps
ATI
Identification
This command causes the modem to send the required information to the
screen depending on the specified parameter.
0 -
Product code
1,2 n/a
3 -
Type of modem and version number of the software
AT&K Flow
control
This command is used to set the flow control of the modem/terminal.
0 -
Flow control off
3 -
RTS/CTS flow control on (default)
4 -
Xon/Xoff flow control on
5 -
Transparent Xon/Xoff flow control on
6 -
Both Xon/Xoff and RTS/CTS flow control on
AT\K Break
control
The modem responds to a break signal received from the terminal (DTE),
a remote modem or the command AT\B according to the specified
parameters. If a break signal is received from the terminal and the modem
is operating in data mode, the operation can be controlled with the
following parameters:
0 -
On line command mode; no break signal is sent
1 -
The data buffers are cleared and a break signal is sent to the
remote modem
2 -
As 0
3 -
A break signal is sent immediately to the remote modem
4 -
As 0