![Alliance Laundry Systems YT050E Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/alliance-laundry-systems/yt050e/yt050e_installation-manual_2901217026.webp)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
70420301 (EN)
24
Before Placing Tumble Dryer into
Service
1. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
2. Check belt tension and adjust if necessary. Refer
to
Adjustments
section.
3. Replace all panels and guards.
4. Turn on electrical supply to tumble dryer.
5. Open the supply valve for gas or steam heated
tumble dryers.
6. After performing the previous checks, start the
tumble dryer by pressing START. (Refer to the
Operating Manual
for detailed instructions.)
Release the start button and open the loading
door. The cylinder should stop rotating within
seven seconds after the door is opened a
maximum of 2 inches (51 mm). If it does not,
adjust the loading door switch. Refer to
Adjustments
section.
7.
Gas tumble dryers:
Start the tumble dryer and
check the burner flame. Adjust the air inlet
shutter as required. Refer to
Adjustments
section.
IMPORTANT: The electronic ignition system will
attempt to light the gas by sparking for the “trial
for ignition” period. If gas does not ignite within
this period, the ignition control will go into a safety
lockout and the valve will no longer open until the
control is reset. It may be necessary to retry several
times to bleed air from the gas lines. To reset, open
and close the loading door and restart tumble
dryer.
If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumble dryer from service.
8. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
9. Check the airflow switch operation refer to
Adjustments
section. The heating systems should
shut off when the lint panel is opened a
maximum of 1.5 inches (38 mm).
The airflow switch operation may be affected by
shipping tape still in place, lack of make-up air,
or an obstruction in the exhaust duct. These
should be checked and the required corrective
action taken before attempting to adjust the
airflow switch. To adjust the airflow switch, refer
to
Adjustments
section.
10. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution. Refer to
.
Figure 10
If the tumble dryer does not meet ANY of the listed
requirements, remove tumble dryer from use. Refer to
Removing tumble dryer from Service
section.
Prepurge
Time
(seconds)
Trial for
Ignition
(seconds)
Reset
Lockout
Condition
By:
Australia
18
10
Press reset
button
CE
18
10
Press reset
button
All Others
1 – 3
10
Open loading
door
T452I
Do not operate tumble dryer if airflow
switch is faulty. An explosive gas mixture
could collect in tumble dryer if airflow
switch does not operate properly.
W407R1
WARNING
T452I
Содержание YT050E