Installation
70420301 (EN)
18
Location Requirements
The tumble dryer must be installed on a level floor.
Floor covering materials such as carpeting or tile
should be removed.
To assure compliance, consult local building code
requirements. The tumble dryer must not be installed
or stored in area where it will be exposed to water and/
or weather.
IMPORTANT: DO NOT block the airflow at the
rear of the tumble dryer with laundry or other
articles. Doing so would prevent adequate air
supply to the combustion chamber of the tumble
dryer.
A typical tumble dryer enclosure is shown in
.
Note the minimum and maximum dimensions. Local
codes and ordinances must be complied with.
IMPORTANT: Install tumble dryers with sufficient
clearance for servicing and operation, refer to
Figure 1
.
Figure 1
WARNING
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumble dryers.
W055R1
TMB2242N
NOTE: Shaded areas indicate adjacent structure.
1
0.5 in. (13 mm) recommended between machines for removal or installation
2
Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim
3
4 in. (102 mm) maximum header thickness
4
12 in. (305 mm) minimum clearance permitted for remainder
5
Guard
6
Provision for make-up air
7
24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
8
0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed
TMB2242N
3
1
4
5
6
7
2
WARNING
To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible
construction must conform to the minimum clearances.
W056R1
8