© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
70420301 (EN)
Specifications and Dimensions
Specifications
50 Pound
75 Pound
F75
Noise level measured during
operation at operator position of
3.3 feet (1 meter) in front of
machine and 5.2 feet (1.6 meters)
from floor.
60 dBA
65 dBA
67 dBA
Net Weight (approximate):
Pounds (kg)
545
(247)
615
(279)
710
(322)
Standard Packaging Weight:
Pounds (kg)
602
(273)
677
(307)
772
(350)
Standard Packaging Shipping
Dimensions: Inch (mm)
41.5 x 52.1 x 81
(1054 x 1323 x 2057)
41.5 x 56.4 x 81
(1054 x 1433 x 2057)
41.5 x 56.4 x 81
(1054 x 1433 x 2057)
Slat Crate Packaging Weight:
Pounds (kg)
669
(303)
742
(337)
837
(380)
Slat Crate Shipping Dimensions:
Inch (mm)
44.5 x 55 x 87.75
(1130 x 1397 x 2229)
44.5 x 59.25 x 87.75
(1130 x 1505 x 2229)
44.5 x 59.25 x 87.75
(1130 x 1505 x 2229)
Cylinder Size:
Inches (mm)
37 x 30
(940 x 762)
37 x 36
(940 x 914)
37 x 36
(940 x 914)
Cylinder Capacity (dry weight):
Pounds (kg)
50
(22.7)
75
(34)
75
(34)
Air Outlet Diameter:
Inches (mm)
8
(203)
8
(203)
10
(254)
Maximum Static Back Pressure:
W.C.I. (mbar)
0.5
(1.3)
0.5
(1.3)
0.5
(1.3)
Maximum Airflow:
C.F.M. (L/sec.)
750
(354)
Gas/Steam 60 Hz 920 (434)
Gas/Steam 50 Hz 750 (354)
Electric
750 (354)
1100
(519)
Motor Horsepower:
Nonreversing
Reversing
Fan
Cylinder
1/2
1/3
1/3
3/4
1/3
1/3
Not Applicable
1
1/3
Gas Models
Gas Connection
1/2 in. NPT
1/2 in. NPT
3/4 in. NPT
Gas Burner Rating:
Btu/hr. (Mj/hr.)
130,000
(137.2)
165,000
(174.1)
225,000
(237.4)
Electric Models
Heating Element Rating:
Kilowatts (kW)
21 kW (240 V/50 Hz)
30 kW (other voltages)
30 kW
Not Applicable
Steam Models
Steam Connection
3/4 in. NPT
3/4 in. NPT
Not Applicable
Steam Coil Rating at 100 psig:
Boiler Horsepower (Btu/hr.)
(recommended operating
pressure 80-100 psig)
5.1
(177,500)
6.1
(210,300)
Not Applicable
Содержание YT050E