Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
28. CABINET TOP (Upper Dryer)
a. While supporting the upper access panel,
remove two screws from bottom edge of upper
access panel. See Figure 7.
b. Gently lower access panel to disengage panel
locators from bottom edge of access panel. See
Figure 7.
c. Remove two screws holding bottom tabs on
front panel to upper dryer cabinet. See
Figures 16 through 19.
d. Swing bottom of front panel away from upper
dryer to disengage hold-down clips from
cabinet top.
e. Disconnect wires from door switch. See
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
f. Remove two screws holding cabinet top to front
flange of cabinet. See Figure 29.
g. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. See
Figure 30.
NOTE: While servicing, cabinet top may be raised
and hinged on the rear hold-down brackets or
supported against wall behind dryer.
Figure 29
Figure 30
CABINET TOP
HOLD-DOWN SCREWS
CABINET
TOP
D252SE1A
D352SE1A
REAR
HOLD-DOWN
BRACKETS