Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
20. CONTROL PANEL AND CONTROLS
(ELECTROMECHANICAL METERED AND
NONMETERED)
(Figure 8)
a. Unlock control panel. See Figure 8A.
b. Pull top of control panel away from control
cabinet and lift up. See Figure 8B.
c. Remove control panel from control cabinet. See
Figure 8C.
d. Disconnect all wires to components. See
e. Remove ground clip holding ground wire to
control panel. See Figure 9.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
f. Loosen setscrew holding switch knob to shaft
and pull knob off shaft. See Figures 10 or 11.
g. Remove knurled nut holding fabric selector
switch to panel and remove switch. See
Figures 10 or 11.
h. Remove hex nut from push-to-start switch and
remove switch. See Figures 10 or 11.
i. Squeeze locking tabs on indicator light and pull
light out from back of panel. See Figures 10 or
11.
Figure 8
Figure 9
CONTROL
PANEL
CONTROL
CABINET
A
B
C
D219SE3B
CONTROL
PANEL
CONTROL
CABINET
D342SE3B
GROUND
CLIP
GROUND
WIRE