505039
77
Section 7 Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
d. Motor Windings (Refer to SECTION 8 for Internal Wiring of the Dryer Motor Switch.)
G. 1
–
2 Ohms between black
wire and orange wire.
Start Winding
H. 1
–
2 Ohms between yellow
wire and orange wire.
I.
Continuity exists between
orange wire and brown wire.
All motor windings check O.K.
Run Main Winding
Protector
NO
YES
NO
NO
YES
YES
Inoperative start winding.
Replace motor.
Inoperative run main
winding. Replace motor.
Inoperative run main
winding. Replace motor.
Disconnect electric power to dryer before performing any of the following steps
or when replacing inoperative motor switch.
W260