![Alliance Laundry Systems SSE007*A3000 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/alliance-laundry-systems/sse007-a3000/sse007-a3000_service_2901336039.webp)
40
505039
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
(3.) Pull the inner side of the coin drop’s front
face plate forward so the inner guide wire
enters the front face plate’s lower hole.
Gently tug coin drop sideways to feel if the
inner guide wire has entered the hole. See
Figure 27.
(4.) Carefully slide coin drop forward into
position, as shown in Figure 28. (Front
face plate of coin drop should be secure
against control cabinet, with coin return
stop completely through slot.)
(5.) Using a 3/8 inch square drive 7/16" socket
with No. 310P4 1/4 inch Ratchet Extension
Tool, reinstall locknut. Tighten locknut
firmly. See Figure 22.
(6.) Reconnect coin drop harness plug. See
(7.) Reinstall ground clip holding ground wire
to control panel. See Figure 9.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
(8.) Reconnect all wires to the control panel
components by referring to the appropriate
wiring diagram. See Figure 9.
(9.) Repeat procedure to service coin drop on
opposite side of control cabinet.
(10.) Reinstall control panel to control cabinet.
See Figure 8.
(11.) Lock control panel.
27. CARD READER
a. Unlock control panel. See Figure 8A.
b. Pull top of control panel away from control
cabinet and lift up. See Figure 8B.
c. Remove control panel from control cabinet. See
Figure 8C.
d. Disconnect all wires to components. See
e. Remove ground clip holding ground wire to
control panel. See Figure 9.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
f. Remove screws holding card reader to control
g. Disconnect wires from card reader at the
connectors.
NOTE: Refer to appropriate wiring diagram when
rewiring the card reader.
h. Carefully remove card reader through control
Figure 27
Figure 28
D228SE1A
INNER
GUIDE
WIRE
FRONT
FACE PLATE
INNER HOLE
FRONT
FACE PLATE
INNER SIDE
D229SE1A
CONTROL
CABINET
COIN RETURN
STOPS