Section 6 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
66. CONVERSION KITS – For Dual Input Gas
Dryers Equipped with No. 56279 Gas Valve
All dual input gas dryers manufactured with glow
bar ignition are factory equipped for
Natural/Mixed gas operation.
No. 56975 Natural/Mixed to L.P. Gas Kit is
available from your parts supplier. This kit
consists of:
No. 56976 L.P. to Natural/Mixed Gas Kit is
available for field conversion. This kit consists of:
67. ORIFICE INFORMATION
1 - 53390
Block-Open Plug and Gasket
1 - 55753
“Valve Converted” Sticker
1 - 56426
L.P. Gas Sticker
1 - 56977
Burner Orifice - Inner
1 - 56978
Burner Orifice - Outer
1 - 56979
Change-Over Sticker
1 - 53952
Vent Screw
1 - 55493
Burner Orifice - Outer
1 - 54944
Burner Orifice - Inner
1 - 56427
Natural Gas Sticker
1 - 56980
Change-Over Sticker
1 - 56981
Valve Number Sticker
Burner Orifice
Kind of Gas
Outer
Orifice
Part No.
Inner
Orifice
Part No.
Stamp
Code
Natural/Mixed
55493
-
37T
-
55494
40
Liquefied
Petroleum (L.P.)
56978
-
53T
-
56977
53
Figure 45
DRY1222S