![Alliance Laundry Systems SE3930 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326041.webp)
53273
41
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
49. MOTOR
a. Remove exhaust fan cover, motor and exhaust
assembly and impeller and housing. Refer to
Paragraph 46, 47 and 48.
b. Disconnect wires from motor switch and
ground wire from motor.
c. Remove two motor clips holding motor to
mounting bracket and lift motor out.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
d. When replacing motor, switch location should
be at 10 o’clock. Refer to Figure 32.
TO REMOVE MOTOR SWITCH
e. Remove two screws holding switch to motor.
f. Disconnect internal motor leads from switch
terminals.
NOTE: Refer to wiring schematic when rewiring
internal motor leads to motor switch.
50. MOTOR AND IDLER PULLEY
ASSEMBLIES
a. Remove motor and exhaust assembly. Refer to
b. Refer to Figure 32 for motor and idler pulley
removal.
Figure 32
DRY860S
Tru-Arc
Ring
Idler
Pulley
Idler
Spring
Motor
Pulley
Ground
Wire
Motor
Clip