30
53273
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
b. Power Cord – Gas Models
(1) Remove access plate.
(2) Remove strain relief.
(3) Remove screw holding power cord ground
wire to terminal block bracket.
(4) Disconnect molex plug and withdraw
power cord.
NOTE: Reconnect ground wire into same hole in
bracket when reinstalling power cord.
26. LOADING DOOR
a. Remove screws holding hinges to door. Refer
to Figure 16.
27. INNER AND OUTER DOOR PANELS AND
DOOR HANDLE
Refer to Figure 17
a. Remove loading door. Refer to Paragraph 26.
b. Remove screws holding handle to door and
separate panels.
IMPORTANT: Do not overtighten screws when
reinstalling door handle and avoid scratching inner
door panel.
28. DOOR STRIKER
Refer to Figure 17
a. Remove screws holding door handle to door.
b. Spread door panels just far enough to depress
tabs on top and bottom of striker and push out.
29. DOOR SEAL
Refer to Figure 17
a. Open loading door and remove seal from inner
door panel.
IMPORTANT: When replacing, be sure seal is not
stretched or distorted and is fastened in place with a
heat resistant adhesive.
Figure 16
DRY849
Hinge
Screws
Lint
Filter
DRY849S