Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Test Electrical Circuit to Ignition System
Refer to Figure 13
1. Single Input Valve
a. Disconnect valve wire harness from dryer
harness at molex plug.
b. Plug dryer power cord into wall receptacle,
set fabric switch and timer (nonmetered
models) or accumulator (metered models)
into position calling for heat and start dryer.
c. Set test meter to read AC voltage and apply
meter probes to WHITE and PINK (or
BROWN) wire terminals on dryer harness
side of molex plug. Meter should register line
voltage in all FABRIC selections except
FLUFF which should read “zero” V.A.C.
2. Dual Input Valve
a. Set test meter to read AC voltage and apply
meter probes to WHITE and BROWN wire
terminals on dryer harness side of molex
plug. Meter should register line voltage in all
fabric settings except fluff which should read
“zero” V.A.C.
b. Set test meter to read AC voltage and apply
meter probes to WHITE and RED wire
terminals on dryer harness side of molex
plug. Meter should register line voltage in
normal and permanent press selections but
“no reading” in delicate or fluff. If no voltage
reading in normal or permanent press, check
130° thermostat and fabric switch.
3. If there is line voltage in Steps 1f, 2b and 2c in
delicate temperature selection, timer switch “b”
and “c” (metered models) or heat circuit
(nonmetered models), high limit thermostat,
motor switch, 120° thermostat and selector
switch are operating properly.
4. Set fabric switch to normal. If meter does not
register line voltage, check 140° thermostat,
fabric switch and wiring.
5. Set fabric switch to permanent press. If meter
does not register line voltage, check timer switch
“b” (metered models), fabric switch, 140°
thermostat and wiring.
To Test Igniter (Glow Bar)
Refer to Figure 13
1. Disconnect wires at igniter molex plug.
2. Set test meter to read ohms and put meter probes
on wire terminals on glow bar side. Meter
should read at least 40 ohms. If “no reading” or
less than 40 ohms, replace glow bar.
IMPORTANT: Always examine all wires,
terminals, connectors and terminal connections
to be sure wiring and connectors are correct
before replacing components.
To Test Sensor (Bi-Meter Switch)
Refer to Figure 13
1. Remove wires from sensor terminals.
2. Set test meter to read ohms and put meter probes
on sensor terminals. Meter should read “zero”
ohms. If meter registers an ohm reading of any
amount, replace sensor.