![Alliance Laundry Systems SE3930 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326045.webp)
53273
45
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
56. REAR BULKHEAD AND HEATER BOX
a. Remove cylinder assembly. Refer to Paragraph
53.
b. Gas Models – Remove burner housing,
Paragraph 23 and heat shroud. Refer to
Paragraph 24.
c. Electric Models – Remove heating element
Refer to Paragraph 37.
d. Remove two hex head screws holding bottom
end of heater box to heat shield. Refer to
Figure 37.
e. Remove Phillips head screw holding rear
bulkhead to terminal block bracket and four
Phillips head screws holding rear bulkhead to
mounting brackets. Refer to Figure 37. Lift
entire assembly out of cabinet.
TO REMOVE HEATER BOX FROM REAR
BULKHEAD
f. Refer to Figure 39 for removal.
Figure 39
DRY866S
Heater Box
Attaching
Screws
Heater
Box
Rear
Bulkhead