![Alliance Laundry Systems SE3930 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326050.webp)
50
53273
Section 6 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
c. Apply thumb pressure to the right side of access
door. When door opens, move door to the left to
disengage from door supports. Refer to
Figure 11.
d. Disconnect igniter wires at quick disconnect
block.
e. Remove hex head screw (located on right side
of burner housing) holding burner tube and
igniter in place.
f. Carefully move burner tube toward rear of
dryer, far enough to permit removal of burner
orifice spud from orifice adapter.
NOTE: Tab on burner tube may have to be
removed from slot in burner housing to obtain
enough clearance.
g. Natural/Mixed to L.P. Gas
56412 Gas Kit:
(1) Turn burner orifice spud out of orifice
adapter and install No. 51211 L.P. Burner
Orifice (metal stamped No. 55). Refer to
Figure 43.
(2) Reinstall burner tube, tighten hex head
screw and reconnect igniter leads.
(3) Remove vent screw and install No. 53390
Block-Open Plug.
(4) Install No. 55753 “Valve Converted”
Sticker to top side of gas valve so it covers
the gas valve part number. Refer to
Figure 39.
(5) Install No. 56426 L.P. Gas Sticker over the
old sticker on rear of cabinet, and apply No.
53408 Change-Over Sticker to the inside of
the loading door opening above the serial
plate.
(6) Connect electrical service and open valve
in gas supply line. Start dryer and observe
burner flame. Adjust air shutter to obtain a
soft, uniform flame. (A lazy, orange tipped
flame indicates lack of air. A harsh, roaring,
very blue flame indicates too much air.)
Adjust air shutter to obtain a soft uniform
blue flame as follows:
(a) Loosen air shutter lockscrew.
(b) Turn air shutter to the right or left as
necessary to obtain proper flame
intensity.
(c) After air shutter is adjusted for proper
flame, tighten air shutter lockscrew
securely.