![Alliance Laundry Systems SE3930 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326022.webp)
22
53273
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
17. FABRIC SWITCH
Refer to Figure 2 or 3
a. Remove two control panel assembly screws
and lift assembly off panel support and/or
control hood.
b. Disconnect wires from switch.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
c. Loosen setscrew, if present, and pull knob off
switch shaft.
NOTE: The type knob in Figure 2 has no setscrew.
d. Remove knurled nut holding switch to control
panel.
18. PUSH-TO-START SWITCH
Refer to Figure 2 or 3
a. Remove two control panel assembly screws
and lift assembly off panel support and/or
control hood.
b. Disconnect wires to switch and remove hex nut
holding switch to control panel.
19. INDICATOR LIGHT
Refer to Figure 3
a. Remove two control panel assembly screws
and lift assembly off panel support and/or
control hood.
b. Disconnect wires from indicator light.
c. Squeeze the locking tabs on back of indicator
light together and push indicator light forward
out of control panel.
IMPORTANT: Pressing on center of lens when
installing INDICATOR LIGHT may break lens.
Insert light into control panel by pressing firmly
against trim.
To Test Push-To-Start Switch
1. Remove control panel and disconnect wires on
switch.
2. Set test meter to read ohms and put meter probes
on switch terminals. You should get “no
reading” on meter.
3. Depress switch button and meter should register
“zero” reading.
To Test Fabric Switch
3 Position
1. Remove control panel and disconnect all wires
from switch.
NOTE: Refer to appropriate wiring diagram
when rewiring switch.
2. Set test meter to read ohms and apply meter leads
to terminals:
a. L2 and 2 – “zero” reading in normal.
b. L2 and C – “Zero” reading in delicate.
3. Meter should give “no reading” in L2 and 2, and
L2 and C in fluff.
4 Position
1. Remove control panel and disconnect all wires
from switch.
NOTE: Refer to appropriate wiring diagram
when rewiring switch.
2. Set test meter to read ohms and apply meter leads
to terminals:
3. Meter should GIVE “no reading” in L1 to C or
L2 to C in delicate or fluff.
4. Meter should give “no reading” in C to 1 in
delicate.
L1 and C
“Zero” reading in Normal
L1 and 2
L2 and 2
2 and C
L2 and C
“Zero” reading in Permanent
Press
2 and C
L1 and 2
“Zero” reading in Delicate
2 and 1