![Alliance Laundry Systems SE3930 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326010.webp)
10
53273
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2. MOTOR OVERLOAD PROTECTOR CYCLES REPEATEDLY
3. MOTOR RUNS BUT CYLINDER DOES NOT TURN
4. MOTOR DOES NOT STOP
POSSIBLE CAUSE
TO CORRECT
Low voltage.
• Refer to Installation Instructions (supplied with dryer)
for electrical requirements.
Clothes load too large.
• Remove part of load. A normal washer load is a normal
dryer load.
Clothes cylinder is binding.
• Check cylinder for binding and “out of round” condition.
• Check front and rear bulkheads for warping.
• Check cylinder rollers for binding.
• Check cylinder seals and glides for wear or damage.
Inoperative motor overload protector.
• Replace drive motor.
POSSIBLE CAUSE
TO CORRECT
Motor drive pulley loose.
• Tighten setscrew. Refer to Figure 32.
Broken cylinder belt.
• Replace belt.
Cylinder belt is upside down or twisted.
• Install properly.
Clothes cylinder is binding.
• Check cylinder for binding and “out of round” condition.
• Check front and rear bulkheads for warping.
• Check cylinder rollers for binding.
• Check cylinder seals and glides for wear or damage.
Broken or disconnected idler lever spring.
• Replace or reconnect spring. Refer to Figure 32.
POSSIBLE CAUSE
TO CORRECT
Inoperative door switch.
• Test switch and replace if inoperative.
Inoperative timer – nonmetered models.
• Test timer and replace if inoperative.
Inoperative accumulator - metered models.
• Test accumulator and replace if inoperative.
Incorrect wiring.
• Refer to appropriate wiring diagram.