513447
67
Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
42. Heater Assembly (Electric
Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
c. Disconnect wires from heater assembly.
NOTE: Refer to wiring diagram when rewiring
heater assembly.
d. Set meter to read Ohms. Apply meter probes to
the heater assembly terminals. Meter should
read as follows: (Cold Ohms).
43. Cycling or Limit Thermostat
a. While supporting the access panel, remove two
screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
c. Label and disconnect wires from thermostat.
NOTE: Refer to wiring diagram when rewiring
thermostat.
d.
Cycling Thermostat (S.P.S.T. – 2 Terminals)
or Limit Thermostat
(1) Set meter to read Ohms.
(2) Apply meter probes to the thermostat
terminals.
(3) Meter should read “zero.”
e.
Cycling Thermostat (S.P.D.T. – 3 Terminals)
(1) Set meter to read Ohms.
(2) Apply meter probes to terminals 1 and 3.
Meter should read “zero”.
(3) Remove screws holding thermostat to
blower fan cover.
(4) Heat thermostat with a small flame until a
distinct “click” is heard, then immediately
apply meter probes to terminals 1 and 2.
Meter should read “zero”.
44. Door Switch
a. While supporting the access panel, remove two
screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. Swing bottom
of front panel away from dryer far enough to
disengage hold-down clips and locators from
cabinet top.
d. Disconnect wires from door switch.
NOTE: Refer to model wiring diagram when
rewiring door switch.
e. Set meter to read Ohms and apply meter probes
on switch terminals 1 and 3 with door closed.
You should get “zero” reading.
f. Apply probes to terminals 1 and 2 with door
closed. The meter should read “infinite”.
g. Open door. Meter should read “infinite”
between 1 and 3 and “zero” between 1 and 2.
Heater
Element
Color
Code
KW Voltage/Hz. Resistance Reading
Red
5
240 V 60
Hz.
10.39 ± .31 Ohms Cold
White
4.75
208 V 60
Hz.
8.2 ± .5 Ohms Cold
Green
4.8
240 V 50
Hz.
10.75 ± .32 Ohms Cold
Yellow
4
240 V 50
Hz.
13.03 ± .39 Ohms Cold
Blue
3.1
240 V 50
Hz.
16.7 ± .5 Ohms Cold
Orange
5.35
240 V 60
Hz.
9.72 ± .3 Ohms Cold
Purple
4.25
208 V 60
Hz.
9.27 ± .3 Ohms Cold
Содержание BD3LLFGS401UW01
Страница 2: ......