513447
29
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 4
Electronic Control Troubleshooting
17. Error Codes
Following is a list of possible error codes.
Display
Information
Description
Cause/
Corrective Action
Right most DP
(decimal point)
Lit
Network Communication Error
Communication problem. Wait for 1.5 minutes for error to
clear. If error doesn’t clear, power-down and power-up the
machine. If error persists, replace control or network board.
Alrm
Break-in Alarm Error
Service the door or coin vault switches.
OFF
Break-in Alarm Shutdown Error
Service the door or coin vault switches.
E:OP
Open Temperature Sensor Error
Open temperature sensor circuit wiring. Replace sensor.
E:SH
Shorted Temperature Sensor Error
Short in temperature sensor circuit wiring. Replace sensor.
Err
Coin Error
Invalid coin pulse or inoperative coin sensor. Check coin
drop area and remove obstructions. If error persists,
tampering may have occurred. Evaluate security
procedures.
OP
Open Thermistor
Physical open in the thermistor circuit. Replace thermistor.
SH
Shorted Thermistor
Dead short in the thermistor circuit. Replace thermistor.
Содержание BD3LLFGS401UW01
Страница 2: ......