42
513447
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 5
Coin Drop Troubleshooting
25. Troubleshooting Coin Drop
a. Non-Electronic Coin Drops:
When coin is placed into coin slot, the coin
should roll down drop and be heard dropping into
coin vault. If coin does not fall into coin vault or
if coin drop sensor does not register that coin has
been entered, follow troubleshooting instructions
on following page. Refer to
Figure 1
for path that
coin follows when working properly.
IMPORTANT: Never use oil to correct coin drop
problems. Oil residue will prevent coins from
rolling properly.
IMPORTANT: Do not bend or damage mechanical
parts within coin drop.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Figure 1
DRY2B
Additional coins
following path to
sensor
Coin Drop
Sensor
Coin in
Coin Slot
Содержание BD3LLFGS401UW01
Страница 2: ......