Electronic Control Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
19. No IR Communication
Attempt to communicate with
control using PDA.
Is there a
response of
any kind from
the control?
Check PDA
manual for
correct use of IR.
No
DRY1859S
Check PDA. Set up
comport, baud rate
and consumer IR bit.
Does the
control display
"EIOF" or "-C-"?
If PDA displays
control mismatch,
select proper
control type.
Communication
sequence
checks out.
Yes
Yes
No
Does the
control
respond?
Make sure that
SDIO IrDA card
is installed if
required on PDA.
No
Yes
"-C-"
"EIOF"
Has IR
communication
been turned off?
Turn IR communication on.
Refer to
Programming Manual
.
Change
control.
No
Yes