10
513447
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 3
Dryer Troubleshooting
IMPORTANT: Refer to wiring diagram for aid in testing dryer components.
1. Dryer Motor Does Not Run
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Dryer motor does not run.
Is power cord
plugged in?
Plug in cord.
Is electrical power off or fuse
blown? Check laundry room for
blown or loose fuse(s), or open
circuit breaker(s). The dryer itself
doesn't have an electrical fuse.
Yes
Turn power on or
replace fuse. Check
both fuses for
electric models.
Yes
Is loading
door closed?
Close door.
No
Is door switch
inoperative?
Yes
Test switch and
replace if
inoperative.
DRY1845Sa
Yes
No
No
Yes
Refer to
Adjustments
section to
check start
switch and
start windings.
Check for
foreign
objects
jammed in
blower fan.
Are motor
starting
functions
inoperative,
does motor
not start, or
motor just
hum?
No
Is motor dead,
won't run?
Yes
Refer to
Adjustments
section to check start
switch, start windings
and main windings.
Is timer
properly
set?
No
Reset timer or
try another
cycle.
No
Is timer
inoperative?
Test timer and
replace if
inoperative.
Refer to
Test
Procedures
section.
Yes
Yes
No
Has motor
overload
protector
cycled?
Wait two or
three minutes
for overload
protector to
reset. If
protector
cycles
repeatedly,
refer to next
flowchart.
No
Yes
Is motor
centrifugal
switch sticky
or plugged
with lint?
No
Remove
dust or lint
and spray
with a
cleaner and
lubricant.
Yes
Continued on
next page.
No