36
M412982
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
46. DRIVE GUARD COVER
a. Support drive guard cover and remove screws
that hold guard to rear of tumbler. Refer to
Figure 13.
b. Reinstall drive guard.
Figure 13
T245PE3B
DRIVE
GUARD ATTACHING
SCREWS
DRIVE
GUARD
COVER