24
M412982
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23. LOADING DOOR HINGES
Refer to Figure 3.
a. Open loading door.
b. While supporting door, remove upper and
lower hinge pins that hold door to hinge
brackets.
c. Remove door from hinge brackets.
d. Remove screws holding hinges to door.
e. Remove door switch actuator from upper hinge.
NOTE: Door switch actuator must be reinstalled in
upper hinge when door is reassembled.
24. LOADING DOOR HANDLE
Refer to Figure 3.
a. Open loading door.
b. Remove screws holding door handle to door
frame.
Figure 2
SIGNAL
BUZZER
T217SE3B
FUSE
HOLDER
NUT
IGNITION
CONTROL
NOTE:
CONTROL
BOX COVER
REMOVED.
REAR
FRONT
CONTROL BOX
COVER
TOP VIEW OF TUMBLER