43
503806
Manufactured (Mobile) Home
Installation
The dryer can be installed in a manufactured (mobile) home by following
these instructions:
1.
IMPORTANT: Gas dryers MUST be permanently attached to the
floor at the time of installation. Order No. 526P3 Dryer Installation
Kit for a manufactured (mobile) home installation. Follow the
instructions supplied with the kit.
•
Exhaust duct must be secured to the mobile home structure.
•
Exhust ducts MUST NOT be connected with sheet metal screws or
fasteners which extend into the duct.
•
Exhaust duct MUST NOT be connected to any other duct, vent or
chimney.
2.
Electrical Connections (Electric Dryer Only) must be a 4-wire
connection.
3.
Venting — Dryer MUST be exhausted to the outdoors.
To reduce the risk of fire and combustion gas
accumulation, the dryer MUST BE EXHAUSTED TO THE
OUTDOORS. Refer to Section on Dryer Exhaust
Requirements.
•
The dryer can be exhausted to the outdoors through the back, left, right
or bottom panel. Gas dryers cannot be exhausted out the left side
because of the burner housing.
(continued)
IMPORTANT: Installation must conform to
the Manufactured Home Construction and
Safety Standards, Title 24 CFR, Part 32-80 or
Standard CAN/CSA-Z240 MH.
a
WARNING