13
503806
·
The power cord (pigtail) connection between wall receptacle and dryer
terminal block
IS NOT supplied with dryer.
Type of pigtail and
gauge of wire must conform to local codes and with instructions
mentioned on Pages 16 and 19.
·
The method of wiring the dryer is optional and subject to local code
requirements. See examples below.
D003IE2D
POWER SUPPLY
POWER SUPPLY
3-WIRE GROUNDED NEUTRAL
120/240 VOLT, 60 HERTZ AC 1 PHASE
SERVICE ENTRANCE SWITCH BOX
(SEE NOTE BELOW)
NEUTRAL
WIRE
NEUTRAL
WIRE
METALLIC OR
NON-METALLIC
SHEATHED CABLE
(COPPER CONDUCTOR
ONLY)
PIGTAIL
TO DRYER
(SEE NOTE BELOW)
NEUTRAL
L1
L2
PIGTAIL CONNECTION
L1
L2
DIRECT CONNECTION
NEUTRAL
WALL
RECEPTACLE
INTERMEDIATE
FUSE BOX
(MAY BE
OMITTED IF
SERVICE
ENTRANCE
BOX IS FUSED)
INTERMEDIATE
SHUT-OFF BOX
(MAY OR MAY
NOT BE FUSED)
A typical
30-Amp
Three-wire
Receptacle
NEMA Type
10-30R
30 AMPERE FUSES OR
CIRCUIT BREAKER
TERMINAL BLOCK
IN DRYER
120
±
12
VAC
240
±
12
VAC
120
±
12
VAC
NOTE: The power cord (pigtail) is
NOT supplied with the electric dryer.
Type of pigtail and gauge of wire
must conform to local codes and
instructions.
The method of wiring the dryer is
optional and subject to local code
requirements.
NOTE: Connect the dryer to the power
supply with the MAXIMUM RATED
VOLTAGE listed on the nameplate.
NOTE: Use copper wire only.
Shorter than 15' (4.5 m) use 10 A.W.G.
Longer than 15' (4.5 m) use 8 A.W.G.