background image

49

503806

D242PE0B

5

Remove door strike from door
liner and reinstall on opposite
side.

D245PE0B

8

Remove two door plugs (or four
screws), and reinstall on
opposite side of door opening.

D246PE0B

9

Reinstall four hinge attaching
screws removed in step 1.

D243PE0B

6

Insert two round tabs into holes
in the bottom of door panel, then
push top of door liner into place.

B

A

D244PE0B

7

Reinstall ten screws removed
in step 2.

Содержание 503806R1

Страница 1: ...itch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can...

Страница 2: ...urement 32 Exhaust System Maintenance 32 Directional Exhaust 33 Inside Exhaust 34 Multi Dryer Installation Exhaust Requirements 35 Positioning and Leveling The Dryer 39 Heat Check Electric Dryers 40 B...

Страница 3: ...e or explode 4 Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children This is a safety rule for all appliances 5 Before the dr...

Страница 4: ...r will not operate with the loading door open DO NOT by pass the door safety switch by permitting the dryer to operate with the door open The dryer will stop tumbling when the door is opened Do not us...

Страница 5: ...d 28 DO NOT operate the dryer with missing or broken parts 29 DO NOT by pass any safety devices 30 Failure to install maintain and or operate this machine according to the manufacturer s instructions...

Страница 6: ...1 cm 4 1 1 cm 26 9 68 3 cm 7 7 19 6 cm 4 0 10 2 cm WITH LEVELING LEGS TURNED INTO BASE 15 4 39 1 cm 4 0 10 2 cm D141IE2H 23 5 59 7 cm 36 91 4 cm 43 2 109 7 cm 28 71 1 cm 4 1 1 cm 26 9 68 3 cm 7 7 19...

Страница 7: ...LEGS TURNED INTO BASE 15 4 39 1 cm 4 0 10 2 cm Roughing In Dimensions Nonmetered Models Electric Dryers Gas Dryers D163IE2H 4 1 1 cm 7 7 19 6 cm WITH LEVELING LEGS TURNED INTO BASE 23 5 59 7 cm 28 71...

Страница 8: ...TANT The dryer should have sufficient clearance around it for needed ventilation and for the ease of installation and servicing For maximum drying performance we recommend that more clearance be allow...

Страница 9: ...to use a screw lock then the special bracket located inside the meter case must be used DO NOT use the special bracket if a 1 4 turn lock is used Coin Drawer Security for additional security drill ou...

Страница 10: ...he meter case For additional security this bolt and its accompanying hardware can be reinstalled inside the control hood of your dryer Listed below is the procedure required to install the flat head b...

Страница 11: ...rom door switch NOTE Refer to wiring diagram when rewiring switch 10 Remove two cabinet top hold down screws and install two 10 tamper resistant screws Part No 62853 11 Reinstall door switch front pan...

Страница 12: ...nected to the equipment grounding terminal or lead on the dryer The dryer has its own terminal block that must be connected to a separate branch 60 Hertz single phase circuit AC alternating current ci...

Страница 13: ...OTE BELOW NEUTRAL L1 L2 PIGTAIL CONNECTION L1 L2 DIRECT CONNECTION NEUTRAL WALL RECEPTACLE INTERMEDIATE FUSE BOX MAY BE OMITTED IF SERVICE ENTRANCE BOX IS FUSED INTERMEDIATE SHUT OFF BOX MAY OR MAY NO...

Страница 14: ...cabinet see page 16 Connect the power cord or direct wiring to the appropriate terminal block terminals using the three wire binding 10 32x screws from the accessories pack in the envelope shipped in...

Страница 15: ...elief to the power cord or wires where they enter the dryer cabinet 5 Check the continuity of the ground connection before plugging the cord into an outlet Use an acceptable indicating device connecte...

Страница 16: ...operate the dryer with the access cover removed D170IE2D NEUTRAL WHITE OR CENTER WIRE GROUND TO NEUTRAL WIRE TERMINAL BLOCK POWER CORD OR DIRECT WIRING Three wire STRAIN RELIEF NOT SUPPLIED WITH DRYER...

Страница 17: ...power to the dryer before proceeding 1 Remove the screw holding the access plate to the rear of the dryer cabinet 2 Remove the three screws holding the three wires to the terminal block terminals Save...

Страница 18: ...r cord wires to the terminal block terminals as follows a Red to Red b Black to Black c White to White see NOTE below NOTE When installing the white wire loop the free eyelet end of the ground wire fr...

Страница 19: ...e dryer with the access cover removed D171IE2D NEUTRAL WHITE WIRE TERMINAL BRACKET GROUND SCREW WHITE WIRES TERMINAL BLOCK NEUTRAL TERMINAL L1 TERMINAL BLACK WIRE GROUND WIRE POWER CORD FOUR WIRE STRA...

Страница 20: ...RTOOPERATETHEDRYER The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Volt 60 Hertz AC alternating current circuit protected by a 15 ampere fuse eq...

Страница 21: ...E SAME CIRCUIT WHEN THIS APPLIANCE IS OPERATING DO NOT OVERLOAD CIRCUITS See illustration below To reduce the risk of an electric shock or fire DO NOT use an extension cord or an adapter to connect th...

Страница 22: ...e in doubt as to whether the dryer is properly grounded DO NOT modify the plug provided with the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician If a posi...

Страница 23: ...htening the connection purge remaining air from gas line to dryer until odor of gas is detected This step is required to prevent gas valve contamination Do not use an open flame to check for gas leaks...

Страница 24: ...ied connector to the 3 8 inch NPT National Pipe Thread gas connection at the rear of the dryer see below NOTE When connecting to gas line an equipment shutoff valve must be installed within 6 1 8 m of...

Страница 25: ...essures in excess of 1 2 psig 3 45 kPa The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping...

Страница 26: ...e the risk of accumulating unsafe concentrations of these gases the dryer MUST be exhausted to the outdoors To reduce the risk of fire and the accumulation of combustion gases DO NOT exhaust dryer air...

Страница 27: ...plastic pipe to exhaust the dryer 2 Exhaust Direction The dryer can be exhausted to the outdoors through the back left right or bottom of the dryer EXCEPTION Gas dryers cannot be vented out the left...

Страница 28: ...meter rigid metal duct 0 44 Feet 13 4 m 34 Feet 10 4 m 1 34 Feet 10 4 m 26 Feet 7 9 m 2 26 Feet 7 9 m 20 Feet 6 1 m 3 20 Feet 6 1 m 14 Feet 4 3 m Maximum length of 4 10 2 cm diameter flexible metal du...

Страница 29: ...35 to 40 percent Be sure the opening is large enough to compensate for any louvers If it is necessary to duct make up air to the dryer increase the area of the ductwork by 25 percent to compensate for...

Страница 30: ...ial 2 5 08 cm 2 5 08 cm E Weather hood to ground clearance 12 30 48 cm 12 30 48 cm F Distance from floor or ceiling to hole edge Not Applicable 3 7 62 cm G Area of centered air openings in closet door...

Страница 31: ...undry rugs etc Blockage will decrease airflow through the dryer thus reducing the efficiency of the dryer Hint 1 Minimize exhaust duct length and changes in direction Hint 2 Use rigid exhaust duct or...

Страница 32: ...WATER COLUMN 60 INCHES 1 5 cm 8 Exhaust System Maintenance The dryer interior and the complete exhaust system should be cleaned periodically by a qualified service person to remove any lint build up...

Страница 33: ...shoved against it Any restrictions of the air from the dryer will decrease the drying efficiency and will obstruct the airflow of the dryer sheatchamber To reduce the risk of fire and the accumulatio...

Страница 34: ...usted to the outdoors Gas heated dryers exhaust substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer b...

Страница 35: ...be installed in each dryer s exhaust system see below This will prevent a backdraft when dryer is not in use and will keep the exhaust air in balance within the central exhaust system IMPORTANT Provi...

Страница 36: ...cm 8 inch 20 32 cm 3 8 inch 20 32 cm 9 inch 22 86 cm 4 9 inch 22 86 cm 10 inch 25 40 cm 5 10 inch 25 40 cm 11 inch 27 94 cm 6 11 inch 27 94 cm 12 inch 30 48 cm 7 12 inch 30 48 cm 13 inch 32 62 cm 8 1...

Страница 37: ...hood with hinged damper installed to prevent passage of weather elements insects dust and dirt into the dryers If a weather hood cannot be used the outside end of the main duct should have a sweep el...

Страница 38: ...ould be no greater than that shown in the chart on Page 32 This can be measured with a manometer placed on the exhaust duct approximately two feet 60 96 cm from the dryer see Page 32 All dryers connec...

Страница 39: ...ver Keep the dryer as close to the floor as possible All four legs must rest firmly on the floor so the weight of the dryer is evenly distributed The dryer must not rock Place a rubber cup supplied wi...

Страница 40: ...pe should be warm Burner Flame Gas Dryers During the gas heat check observe the burner flame The flame can be viewed by removing the lower front panel of the dryer Metered Models Set FABRIC SELECTOR s...

Страница 41: ...flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to the left to get a luminous yellow tipped flame then turn it back slowly to...

Страница 42: ...low for lint filter location Cleaning the lint filter is important because a layer or pad of lint on the filter will block the flow of air through the dryer thus reducing the efficiency of the dryer T...

Страница 43: ...extend into the duct Exhaust duct MUST NOT be connected to any other duct vent or chimney 2 Electrical Connections Electric Dryer Only must be a 4 wire connection 3 Venting Dryer MUST be exhausted to...

Страница 44: ...obtain locally To reduce the risk of fire the exhaust duct and weather hood MUST be fabricated of a material that will not support combustion Rigid or flexible metal pipe is recommended for a clothes...

Страница 45: ...990 or phone 920 748 3950 for the name and address of the nearest authorized parts distributor For Energy Conservation Make sure the lint filter is always clean Do not overload dryer Do not overdry cl...

Страница 46: ...or against the dryer The finish could be damaged Use only a damp or sudsy cloth for cleaning the control panel Some spray prewash products may harm the finish on the control panel Label all wires prio...

Страница 47: ...NOT have an electrical fuse xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxx xxxxxxxxxxxxxxxxxxxxxxxx xxxxxx xxx Has the motor overload protector cycled See Page 45 Gas Dryers Only check to see if the gas valv...

Страница 48: ...ly reversible To reverse door proceed as follows 1 Remove four hinge attaching screws D238PE0A D241PE0A 4 Rotate door panel 180 degrees as shown D239PE0A 2 Remove all ten screws D240PE0A 3 Pull top of...

Страница 49: ...o door plugs or four screws and reinstall on opposite side of door opening D246PE0B 9 Reinstall four hinge attaching screws removed in step 1 D243PE0B 6 Insert two round tabs into holes in the bottom...

Страница 50: ...he IMPORTANT SAFETY INSTRUCTIONS Pages 3 5 before operating the dryer continued 5 IN USE LIGHT 3a COIN SLIDE 1 LOADING DOOR 4 PUSH TO START BUTTON 2 FABRIC SELECTOR TEMPERATURE SWITCH LOWER FRONT PANE...

Страница 51: ...ryer is ready to operate Allow the coin slide to return to its normal position or pull it out if necessary Repeat for more time 3b Nonmetered models Turn the timer knob to the number of minutes desire...

Страница 52: ...or your own convenience and protection record the above information and retain your sales slip for this appliance The model and serial numbers will be found on the nameplate located on the inside of t...