17
503806
Four-Wire Power Cord
IMPORTANT: Use only a U.L. listed No. 10 AWG (copper wire only)
four conductor power supply cord kit rated 240 Volts (minimum)
30 Amperes and labeled as suitable for use in a clothes dryer.
NOTE: The power cord is not supplied
with the dryer when the dryer is shipped
from the factory, therefore, disregard
steps 2 and 3 below when connecting a
four-wire power cord to a new dryer.
If the dryer has a three-wire cord
attached, then complete steps 1 through
12.
To reduce the risk of electrical shock, disconnect the
electrical power to the dryer before proceeding.
1.
Remove the screw holding the access plate to the rear of the dryer
cabinet.
2.
Remove the three screws holding the three wires to the terminal block
terminals.
Save these screws.
3.
Loosen the strain relief screw and pull the cord or wires out through
the rear of the dryer.
4.
Remove the terminal bracket ground screw holding the ground wire to
the terminal block mounting bracket.
Save the screw.
NOTE: ON NEW DRYERS, this is the ground wire that goes from the
neutral (center) terminal on the terminal block to the mounting bracket.
STRAIN
RELIEF
NUT
TYPICAL
FOUR-WIRE
RECEPTACLE
POWER CORD
(Four-Wire)
STRAIN
RELIEF
D006IE2B
D106GE2A
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
a
WARNING