18
503806
Install four-wire power cord
5.
Route the end of the four-wire power cord through the strain relief.
DO NOT tighten the strain relief screws at this time.
6.
Insert the end of power cord and strain relief through the hole in the
rear of the dryer cabinet. Install the strain relief nut from the inside of
the cabinet and tighten firmly.
7.
Attach the green ground wire (from the four-wire power cord) to the
terminal block mounting bracket using the hex head screw removed in
Step 4. Tighten the screw firmly.
8.
Using the
three wire-binding
(10-32x
³⁄₈
")
screws from the
accessories envelope located inside the cylinder
(unless
the screws were previously removed in Step 2), attach the power cord
wires to the terminal block terminals as follows:
a. Red to Red
b. Black to Black
c. White to White (see NOTE below)
NOTE: When installing the white wire, loop the free eyelet end of the
ground wire (from Step 4) and place it together with the white wire and
attach both wires to the neutral (center) terminal on the terminal block,
see Page 19.
IMPORTANT: Failure to tighten the nuts firmly on the terminal block
may result in power cord wire failure.
9.
Tighten the two strain relief screws to secure the power cord.
10. Recheck all screws to be sure they are tight.
11. Check the continuity of the ground connection before plugging the cord
into an outlet. Use an acceptable indicating device connected to the
center grounding pin of the plug and the green screw on the back of the
cabinet. (See illustration on page 15.)
12. Reinstall the access plate and screw to the rear of the dryer cabinet.