HOSE & REGULATOR ASSEMBLY AND REPLACEMENT

7

Glass beads warning:

    1. This fire table comes equipped with a standard LP gas hose and regulator including the appliance side connection for a CGA

         No 791 Cylinder Connection Device. The LP gas hose and regulator supplied with this fire table must be used. Only a hose

         and regulator specified by manufacturer can be used for replacement.

      a. The CGA No 791 connection incorporates a magnetic flow limiting device that acts to limit the flow of gas if a leak is

          detected between the regulator and the burner valves.

      b. If the burner valve is open prior to the LP gas cylinder service valve being opened. The connection will interpret this

          free flow of gas to be a leak.

      c. The connection safety feature will reduce gas flow from the regulator to the appliance to a minimal level.

      d. Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to ensure that the

          connection flow limiting device is not triggered mistakenly.

      e. If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder service valve and the burner valve,

           wait 10 seconds to allow the device to reset, open the cylinder service valve, then open the burner valve and light the

           firepit as per lighting instructions.

   2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts any hot surface.

   3. Regular maintenance of the hose and regulator:

      a. Inspect the hose before each use of the fire table. If  the hose shows signs of cracks, abrasions, cuts or damage of any

         kind, do not operate the appliance. Fix or replace the hose as required before using the appliance, For assistance with 

         repair or replacement of the hose, call our customer service department at 1-866-439-9800. Use only replacement parts 

         from the manufacturer.

    b. Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when replacing the cylinder or at least 

        once per year. If there is any indication of damage, have the seal replaced by a certified gas dealer before operating 

        the appliance.

   4. Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve. Hand tighten only.  

   5. Be careful to not cross the threads on the connection when tightening the CGA No 791 connection on to the LP gas

        cylinder service valve.

   6. “ Leak Test ” should always be performed after attaching the connection to the LP gas cylinder service valve. (See

       “ Checking for Leaks” section of this manual on page 14).

   7. For the connection of the hose and regulator to the LP tank, refer to the “ Connection ” section of the LP gas cylinder 

        section above. 

     

 

         

      

          

          

1. Glass media may have sharp edges. Wear safety glasses and gloves when handing.

2. Do not change or substitute the glass media material provided with this fire pit, If replacing, use only replacement

    glass media available from your local authorized dealer/distributor.

3. Pour the glass media evenly in to the burner area (with the exception of the screen- if applicable). The glass should

   be  1/2 ” above the burner. 

4. 

IMPORTANT:

Do not exceed a height of 1” above the burner when placing glass media. Ensure no media covers 

    the igniter screen. store any excess media in a safe location.

5. Keep away from the unit for the first 20 minutes after igniting your unit for the first time, as glass beads could pop 

    out and cause injury. Should any glass beads pop out, discard them.

6. Always ensure that glass beads are completely dry before use. 

   Failure to do so will cause them to crack or pop. 

 

Содержание 4143697

Страница 1: ...rademarks of LF LLC All rights reserved 1 Questions problems missing parts Before returning to your retailer call our customer service department at 1 866 439 9800 8 a m 8 p m EST Monday Sunday Serial...

Страница 2: ...If odor continues leave the area immediately After leaving the area call your gas supplier or fire department explosion which could cause property damage personal injury or death WARNING Do not store...

Страница 3: ...AAA Battery Burner Bowl 7 8 9 10 11 Burner Ring Pilot Housing Manual Electric Igniter Control Knob Regulator Hose Assembly 1 1 1 1 1 1 1 1 1 1 1 WARNING Failure to position the parts in accordance wi...

Страница 4: ...mperatures and should stay away to avoid burns or clothing ignition young children should be carefully supervised when they are in the area of the appliance clothing or other flammable materials shoul...

Страница 5: ...e Always shut off the supply at the tank valve and disconnect regulator from the tank when the fire table is not in use DO NOT sit on the fire table when the unit is in operation DO NOT throw anything...

Страница 6: ...t store a spare LP gas cylinder under or near this appliance b Never fill the LP gas cylinder beyond 80 full c If the information in a and b is not followed exactly a fire causing death or serous inju...

Страница 7: ...e appliance For assistance with repair or replacement of the hose call our customer service department at 1 866 439 9800 Use only replacement parts from the manufacturer b Inspect the seal inside the...

Страница 8: ...Installation Instructions 8 Place the table lid 1 over the burner bowl of the table 2 1 1 Place the glass beads 3 to the burner bowl 2 2 3 Place the polyester cover 4 over the fire table after use 3...

Страница 9: ...tight Connecting LP Gas Tank 1 Before connecting be sure there is no debris caught in the head of the LP gas tank head of the regulator valve or in the head of the burner or burner ports 2 Connect re...

Страница 10: ...bubbles appear turn LP gas tank valve to CLOSED reconnect and re test b If you continue to see bubbles after several attempts turn LP gas tank valve to CLOSED and disconnect LPgas tank per Disconnect...

Страница 11: ...isually check the burner flames to make sure your outdoor firepit is working properly Figure 7 5 See below for proper cleaning instructions 6 Check all gas connections for leaks 7 Check components for...

Страница 12: ...turi tube Clean burner venturi tube Burner ports clogged or blocked Clean burner ports Sudden drop in gas flow or reduced flame height Out of gas Exchange refill or replace LP gas tank Overfilling pre...

Страница 13: ...espartsplus com Printed in China PART DESCRIPTION PART 1 866 439 9800 Table Lid 4143697 1 1 2 3 4 5 6 7 8 9 10 11 1 PART DESCRIPTION PART Burner Ring 4143697 7 2 3 4 5 6 7 8 9 10 11 Table Glass Beads...

Страница 14: ...17 s appliquant aux appareils d coratifs au gaz pour l ext rieur Proposition 65 de la Californie Cet article peut vous exposer au monoxyde de carbone qui est un sous produit de combustion reconnu par...

Страница 15: ...z toute amme nue Si l odeur persiste loignez vous imm diatement de l endroit o vous vous trouvez de gaz ou le service d incendie AVERTISSEMENT liquide ou vapeur in ammable proximit de cet appareil ou...

Страница 16: ...Anneau du br leur Bo tier de la veilleuse Bouton d allumage lectrique manuel Bouton de commande Ensemble de r gulateur et de tuyau 1 1 1 1 1 1 1 1 1 1 1 AVERTISSEMENT Un assemblage des pi ces non conf...

Страница 17: ...t s et de l arri re Ne placez pas la table avec SI VOUS D TECTEZ UNE ODEUR DE GAZ Fermez l alimentation en gaz de la table avec foyer au gaz int gr teignez toute flamme nue Ne tentez pas d allumer un...

Страница 18: ...nt gr est allum e Coupez toujours l alimentation du robinet de la bouteille et d branchez le r gulateur de la bouteille lorsque vous n utilisez pas la table avec foyer au gaz int gr Ne vous asseyez PA...

Страница 19: ...types de capuchon ou de bouchon peuvent laisser fuir le propane a Ne rangez pas de bouteille de propane de rechange sous l appareil ni proximit de celui ci b Ne remplissez jamais la bouteille de propa...

Страница 20: ...aide concernant la r paration ou le remplacement du tuyau appelez notre service la client le au 1 866 439 9800 Servez vous uniquement des pi ces de rechange du fabricant b V rifiez le joint d tanch i...

Страница 21: ...21 Placez le couvercle de la table 1 sur la cuvette du br leur de la table 2 1 1 Placez les perles en verre 3 dans la cuvette du br leur 2 2 3 Placez la housse en polyester 4 sur la table avec foyer...

Страница 22: ...d une montre jusqu ce qu il soit serr Raccord de la bouteille de propane 1 Avant de faire le raccord assurez vous qu aucun d bris ne vient obstruer la t te de la bouteille de propane le robinet du r g...

Страница 23: ...e robinet de la bouteille de propane la position CLOSED ferm et d branchez la bouteille de propane comme indiqu la rubrique D branchement de la bouteille de propane Composez le 1 866 439 9800 pour obt...

Страница 24: ...re 7 5 Voir ci dessous pour prendre connaissance des instructions de nettoyage ad quates 6 V rifiez toutes les connexions pour vous assurer qu il n y a pas de fuite 7 V rifiez si les pi ces montrent d...

Страница 25: ...vent dans le tuyau du br leur ou de venturi Nettoyez le tuyau du br leur ou le tuyau de venturi Les orifices du br leur sont obstru s Nettoyez les orifices du br leur Baisse soudaine du d bit de gaz o...

Страница 26: ...t les usages industriels ou commerciaux de l article La garantie exclut tout dommage caus l article durant l exp dition ou tout d faut r sultant d une modification ou d un usage abusif ou inappropri d...

Отзывы: