28
Note:
In POLY-VELOCITY mode, all expression information is sent in key velocity
form. Changes in velocity will occur only when a new key is struck. Consequently, if
you change the position of the Swell pedal after a key is struck there will be no change in
velocity until a new key is struck. Use this mode only when a velocity-sensitive external
MIDI device is connected. If this mode is selected when recording to a sequencer, the
expression on the organ will not function when playing back from the sequencer.
SWELL-VOLUME
— This setting causes MIDI expression data to be sent only on the
Swell MIDI channel.
Some early sequencers can only interpret one volume message.
NO EXPRESSION
— No MIDI expression (volume) data sent.
8. MIDI Sustain Kick Switch
(optional)
A lever located to the left of the expression shoe and controlled by the organist’s foot,
operates MIDI sustain. This function can be assigned to any one of or all of the
instrument’s manuals. Advance to the 'MIDI SUSTAIN' window function
(see Section
A-2)
.
To select an organ keyboard (manual), press the
CURSOR
button until the cursor is
positioned on the manual abbreviation. Turn the
ROTARY DIAL
to select an organ
keyboard. Then, to turn the MIDI Sustain function on/off on the selected manual, press
the
CURSOR
button until the cursor is positioned on the MIDI Sustain value. Turn the
ROTARY DIAL
to turn the selected manual
ON/OFF.
OFF
will not allow MIDI
Sustain messages to be transmitted,
ON
will allow MIDI sustain messages to be
transmitted on a given keyboard (manual) or MIDI channel. For example, when a
PIANO
voice in an external MIDI device (voice module) is selected and the MIDI
sustain for that given MIDI channel (division) is turned
ON,
and the foot controlled
sustain lever is actuated, the piano sound will slowly decay.
9. Organ Local Off
Organ Local Off is a function that allows the user to “virtually” disconnect the organ’s
keyboards, pedalboard and pistons from the organ’s tone generation and capture system.
In essence, the organ is transformed into a sophisticated multi-manual MIDI controller.
To enable/disable the Organ Local Off function, advance to the ‘ORGAN LOCAL OFF’
window function
(see Section A-2)
.
To enable/disable the Organ Local Off function, press the
CURSOR
button until the
flashing cursor is positioned on the Local Off control value. Turn the
ROTARY DIAL
to change the enable/disable value.
Note:
When Organ Local Off is enabled, the MIDI stops do not need to be on to play the
external MIDI device(s).
MIDI SUSTAIN
GT = OFF
ORGAN LOCAL OFF
= DISABLED
ORGAN LOCAL OFF
= ENABLED