Plan the Kinetix 5700 Drive System Installation
Chapter 2
Figure 14 - Minimum Clearance Requirements
MOD
NET
2
1
1
4
I/O
MODULE
STATUS
MOD
DC BUS
29.5
(1.16)
Clearance right of the
module is not required.
Clearance left of the
module is not required.
Kinetix 5700 Drive Module
(DC-bus power supply is shown)
100 mm (3.94 in.) clearance below
module for airflow and installation.
40 mm (1.57 in.) clearance above
module for airflow and installation.
Refer to the Kinetix Servo Drives Technical
Data, publication
, for
Kinetix 5700 drive module dimensions.
Kinetix 5700 Capacitor or Extension Module
(2198-CAPMOD-2240 module is shown)
Clearance above for wiring to DC-bus
studs and lug cover installation.
Clearance where cover and
DC-bus cabling attaches.
IMPORTANT
Mount the drive module in an upright position as shown. Do not mount the module on its
side.
Kinetix 5700 Drive Modules
Drive Module Cat. No.
Clearance Above,
min
mm (in.)
Clearance Below,
(1)
min
mm (in.)
(1) Additional clearance can be required depending on the actual wiring harness being installed.
DC-bus power supply
2198-P031
2198-P070
2198-P141
2198-P208
40 (1.57)
100 (3.94)
Single-axis inverters
2198-S086-ERS
x
2198-S130-ERS
x
2198-S160-ERS
x
40 (1.57)
100 (3.94)
Dual-axis inverters
2198-D006-ERS
x
2198-D012-ERS
x
2198-D020-ERS
x
2198-D032-ERS
x
2198-D057-ERS
x
40 (1.57)
100 (3.94)
iTRAK power supply
2198T-W25K-ER
40 (1.57)
100 (3.94)
Capacitor module
2198-CAPMOD-2240
115 (4.53)
100 (3.94)
Extension module
2198-CAPMOD-DCBUS-IO