Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
113
Connect the Kinetix 5700 Drive System
Chapter 5
Figure 72 - MP and BC Connector Wiring (single-axis inverters)
You can attach the motor power wires to the motor power connector, plug in
the motor feedback and brake connectors, and then connect the bracket to the
drive.
Table 60 - Motor Power (MP) Connector Specifications (single-axis inverters)
2
1
1
I/O
5
UFB
MOD
NET
2
1
6
10
–
MBRK
+
W V
U
–
MBRK
+
Motor Cable
Shield Clamp
Motor Power
(MP) Connector Plug
2198-S
xxx
-ERS
x
Single-axis Inverters
(2198-S086-ERS
x
drive is shown)
Motor Brake
(BC) Connector Plug
Motor Cable
Shield Clamp
Motor Power
Connector
Motor Cable Bracket
Connector Flange Screws (2)
0.8 N•m (7.1 lb•in)
Tie Wrap
WARNING:
Make sure the motor power connections are correct when wiring
the MP connector plug. Insert the plug into the module connector and
tighten flange screws to 0.8 N•m (7.1 lb•in). Incorrect wiring/polarity or
loose wiring can cause an explosion or damage to equipment.
Drive Module
Cat. No.
Pin
Signal/Wire Color
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Terminal
Torque Value
N•m (lb•in)
Flange
Torque Value, max
N•m (lb•in)
2198-S086-ERS
x
2198-S130-ERS
x
Motor power cable
depends on motor/
drive combination.
6…16
(1)
(10…6)
20.0 (0.79)
2.5…4.5
(22…40)
0.8
(7.1)
(1) Building your own cables or using third-party cables for Kinetix VP motors is not an option. Use 2090-CS
x
M1DE/DG single motor cables. Refer to the Kinetix
Motion Accessories Specifications Technical Data, publication
, for cable specifications.
U
V
W
Brown
Black
Blue
Green/Yellow
U
V
W