Manual
SmartHandle AX
36 / 55
SimonsVoss
6 | Configuration
2. Change to the [Configuration/Data] tab.
3. Click on the Extended configuration button.
ð
The "Extended configuration" window will open.
Turn off LED/
beeper
ü
LSM open.
ü
"Extended configuration" window open.
1. Enable the Turn off LED checkbox or the Turn off beeper
checkbox.
2. Click on the OK button.
ð
Window closes.
3. Click on the Apply button.
4. Click on the Exit button.
5. Execute programming (see ).
ð
LED or beeper is switched off.
6.12 Deactivate freeze mode
If the second battery warning level is ignored, the SmartHandle
automatically switches to freeze mode. Once at this warning level,
SmartHandle can only be activated using a G2 battery replacement ID
medium. Freeze mode prevents the batteries from being discharged
completely, so that the locking device can be opened one more time.
ü
Add battery replacement identification medium (see LSM manual).
ü
Battery replacement identification medium programmed.
1. Activate the battery replacement identification medium on the locking
device.
ð
Freeze mode is deactivated for about thirty seconds.