Manual
SmartHandle AX
30 / 55
SimonsVoss
6 | Configuration
6 Configuration
6.1 Pulse length
SmartHandle is pre-set to engage for about 5 seconds. The time that it
engages can be freely configured between 1 and 25 seconds for each lock
in the software. This does not result in a shorter battery life.
6.2 Access control
Identification media bookings are logged if access control is activated. The
following information is stored in SmartHandle.
–
Date
–
Time
–
Identification medium ID
Each SmartHandle AX can store up to 3,000 bookings.
IMPORTANT
These settings are only available in the .ZK version.
ü
LSM open.
1. Double-click on the SmartHandle AX entry in the matrix to open the
settings.
2. Change to the [Configuration/Data] tab.
3. Enable the Audit trail checkbox.
4. Click on the Apply button.
5. Click on the Exit button.
ð
Access control is enabled.
Only authorised transponder operations are logged by default. However,
you can also log non-authorised bookings (see
). You will find information on how to read
access lists in the LSM manual.
6.3 Time zone control
You can load a time zone plan. Identification media will then be granted or
denied access based on their time zone group. Up to 100+1 time groups