3. Turn ATPOL II on. Enter PSM and note that PSM has successfully connected to ATPOL II. This
will be clear by the box on the main menu with the words “Unit Connected” appearing within a large
green banner. Note that the box also says “Serial Comm: enabled” and “Datalogging: enabled”.
4. We recommend that you either run through the checkout connections feature explained in the
Checking out Connections using ATPOL II
section or take a snapshot of the waveforms and look at
them for errors, if you have a computer handy, as described in the
Checking out Connections using
PSM
section.
5. If you intend to have ATPOL II start monitoring by direct command via the keypad or via PSM, this
is the time to do it. Otherwise, it will start when the programmed start time occurs.
6. When satisfied that all is correct, download waveset1 from ATPOL II (see the
section), giving it a unique filename, so you have a record of the signals
just prior to starting logging. Waveset1 is stored inside ATPOL II automatically when you start
monitoring.
7. When you are done logging, capture another set of waveforms, giving it a unique name. Combining
this waveset with the one that was captured when logging began gives a before and after picture of
the power for use in later presentations or as a troubleshooting aid if the data log appears to contain
bad data.