Concrete slab without foundation frame
In order to use a concrete slab without a foundation frame, the
following requirements must be met:
– The procedures/specifications for preparing the concrete slab
will be the same ones used for preparing a concrete slab with
a foundation frame.
– The base frame must be attached with expansion bolts that can
each withstand a pull-out force of at least 40 kN (9000 lbf).
The expansion bolts should be mounted in the holes normally
used for attaching the base frame to the foundation frame.
– Installation is prohibited when wind speeds are in excess of
15 m/sec. (33 mph).
– The maximum height allowed for the first tie is 6 meters
(20 ft).
– The type of installation must be approved by the local gover-
ning authorities.
Transportable foundation
In order to use a transportable steel foundation, the following
requirements must be met:
– The steel foundation must conform to all of Alimak’s specifi-
cations. (These can be ordered separately from an Alimak
representative).
– The type of installation must be approved by the local gover-
ning authorities.
ALIMAK 34791 - 1/01
G
8