ALIMAK 34785 - 1/01
Concrete slab on the ground
Advantage:
No drain required.
Disadvantage:
High sill.
Concrete slab level with the ground
Advantage:
No drain required.
Disadvantage:
Sill.
A concrete slab level with the ground is the most common type
of foundation. A ramp up to the level of the sill is usually made
of fill, wood or steel.
Concrete slab below ground level
Advantage:
No sill between ground level and hoist car.
Disadvantage:
Corrosion if water remains on the foundation
and does not drain.
This alternative requires draining.
IMPORTANT: Please note that the foundation must always be
isolated, or the surrounding soil prevented from freezing, if there
is a risk of frost heave.
Min. 100 mm (4’’) gravel
Drain pipe with outlet
(dia. 2’’)
Ground
level
Ground
level
Enclosure/
Car sill
Enclosure/
Car sill
Ground
level
Enclosure/
Car sill
Minimum 30 mm (1 1/4’’) concrete
cover or according to local regulations
To lower edge of
reinforcement
Hole Ø 50 mm in slab
400
(1’ - 3 3/4’’)
270
(10 3/4’’)
add concrete pit
height when
applicable
G
2
Содержание Scando 650 DOL
Страница 4: ......
Страница 6: ...2 8 m car base structure 9 2 1 4 3 5 m car base structure 11 5 3 4 ...
Страница 16: ...A10 ...
Страница 32: ......
Страница 38: ...B5 ...
Страница 92: ......
Страница 94: ......
Страница 106: ......
Страница 108: ......
Страница 116: ...H8 ...
Страница 132: ......
Страница 134: ......
Страница 140: ......
Страница 141: ...HOIST capacity 2400 kg or 24 passengers 9101286 101 ...
Страница 142: ......
Страница 144: ......