36
www.Observint.com
4. Select the type of event you want to be displayed on the image.
5. Click
OK
to save your settings.
Full Screen Monitoring
When an alarm is triggered, the local monitor (VGA or HDMI) the video image from the alarming channel configured for full screen
monitoring is displayed.
If alarms are triggered simultaneously in several channels, their full-screen images will be switched at an interval of 10 seconds
(default dwell time). A different dwell time can be set by going to
Menu | Configuration | Live View
and then changing the
Full Screen Monitoring Dwell Time
setting.
Auto-switch will terminate when the alarm condition ends. The NVR will revert to the Live View interface.
NOTE
You must select the channel(s) you want to display with full screen monitoring in the “Trigger Channel” settings menu.
Audible Warning
Trigger an audible beep when an alarm is detected.
Email Linkage
Send an email with alarm information to a user or users when an alarm is detected. The Email networking feature must be
configured for email to be sent.
Trigger Alarm Output
Trigger an alarm output when an alarm is triggered.